Write Calibration Training Fail

Possible Reason
Marginal issues on CA, Write DQ/DQS, or Read DQ/DQS. When the Write Calibration training fails, a dialog box appears as shown in the following figure.
Figure 1. Write Calibration Training
Graphical user interface, text, application Description automatically generated
Workaround
Configure any one of the following parameters to a different value using the MSS Configurator when the Write Calibration training fails:
  • Memory CA ODT
  • FPGA DQ Drive
  • FPGA DQS Drive
  • FPGA DQ ODT
  • FPGA DQS ODT
  • Memory Pull-Down Drive Strength
The following figure shows the configuration of DQ/DQS drive or ODT in the DDR Controller tab.
Figure 1. Configuring DQ/DQS Drive or ODT—DDR Controller Tab
???
The following figure shows the configuration of pull-down drive strength or CA ODT in the DDR Memory Initialization tab.
Figure 2. Configuring Pull-Down Drive Strength or CA ODT—DDR Memory Initialization Tab
???