AC Write Characteristics

Table 1. AC Write Characteristics(1)
Parameter Symbol Minimum Maximum Units
Address, OE Setup Time tAS, tOES 0 ns
Address Hold Time tAH 100 ns
Chip Select Setup Time tCS 0 ns
Chip Select Hold Time tCH 0 ns
Write Pulse Width (WE or CE) tWP 200 ns
Data Setup Time tDS 100 ns
Data, OE Hold Time tDH, tOEH 10 ns
Note:
  1. 1.All write operations must be preceded by the SDP command sequence.