41.10.2 Power-On Reset (POR) Characteristics

Table 41-19. POR Characteristics
ParameterConditionsSymbolMin.Typ.Max.Unit
Voltage threshold level on VDDin risingVDD falls at 1V/ms or slowerVPOT+1.271.431.59V
Voltage threshold level on VDDin fallingVPOT-0.690.971.32V
Figure 41-2. POR Operating Principle