49.30 I2C Electrical Specifications

Figure 49-16. I2C Start/Stop Bits Host Mode Timing Diagrams
Figure 49-17. I2C Bus Data Host Mode Timing Diagrams
Table 49-42. I2C Host Mode Electrical Specifications
AC CHARACTERISTICSStandard Operating Conditions: VDD = AVDD = 1.62V to 3.63V (unless otherwise stated)

Operating temperature: -40°C ≤ TA ≤ +85°C for Industrial

Param. No.SymbolCharacteristicsMin.Max.UnitsConditions
I2CM_1TLO:SCLHost Clock Low Time100 kHz mode4.7µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode1.3µs
1 MHz mode0.5µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode160nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CM_3THI:SCLHost Clock High Time100 kHz mode4µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode0.6µs
1 MHz mode0.26µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode60nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CM_5TF:SCLSDAx and SCLx Fall Time100 kHz mode300nsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode300ns
1 MHz mode120nsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode40nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CM_7TR:SCLSDAx and SCLx Rise Time100 kHz mode1000nsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode300ns
1 MHz mode120nsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode40nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CM_9TSU:DATData Input Setup Time (1)100 kHz mode250nsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode100ns
1 MHz mode50nsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode10nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CM_11THD:DATData Input Hold Time100 kHz mode300µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode300µs
1 MHz mode300µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode5nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CM_13TSU:STAStart Condition Setup Time100 kHz mode4.7µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode0.6µs
1 MHz mode0.26µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode160nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CM_15THD:STAStart Condition Hold Time100 kHz mode4.0µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode0.6µs
1 MHz mode0.26µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode160nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CM_17TSU:STOStop Condition Setup Time100 kHz mode4.0µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode0.6µs
1 MHz mode0.26µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode160nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CM_21TAA:SCLOutput Valid from Clock100 kHz mode3.45µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode0.9µs
1 MHz mode0.45µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode0.1µsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CM_23TBF:SDABus Free Time (2)100 kHz mode4.7µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode1.3µs
1 MHz mode0.5µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode160nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
Note:
  1. Longest delay between data hold timing based on bitfield SDAHOLD of register CTRLA from SERCOM Module and timing based on 4 period of GCLK_SERCOM for 100kHz/400kHz/1MHz mode.
  2. The amount of time the bus must be free before a new transmission can start (STOP condition to START condition).
Figure 49-18. I2C Start/Stop Bits Client Mode Timing Diagram
Figure 49-19. I2C Bus Data Client Mode Timing Diagrams
Table 49-43. I2C Client Mode Electrical Specifications
AC CHARACTERISTICSStandard Operating Conditions: VDD = AVDD = 1.62V to 3.63V (unless otherwise stated)

Operating temperature: -40°C ≤ TA ≤ +85°C for Industrial

Param. No.SymbolCharacteristicsMin.Max.UnitsConditions
I2CS_1TLO:SCLClient Clock Low Time100 kHz mode4.7µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode1.3µs
1 MHz mode0.5µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode160nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CS_3THI:SCLClient Clock High Time100 kHz mode4.0µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode0.6µs
1 MHz mode0.26µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode60nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CS_5TF:SCLSDAx and SCLx Fall Time100 kHz mode300nsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode300ns
1 MHz mode120nsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode40nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CS_7TR:SCLSDAx and SCLx Rise Time100 kHz mode1000nsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode300ns
1 MHz mode120nsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode40nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CS_9TSU:DATData Input Setup Time100 kHz mode250nsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode100ns
1 MHz mode50nsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode10nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CS_11THD:DATData Input Hold Time (1)100 kHz mode300µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode300µs
1 MHz mode300µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode5nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CS_13TSU:STAStart Condition Setup Time100 kHz mode4.7µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode0.6µs
1 MHz mode0.26µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode160nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CS_15THD:STAStart Condition Hold Time100 kHz mode4.0µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode0.6µs
1 MHz mode0.26µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode160nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CS_17TSU:STOStop Condition Setup Time100 kHz mode4.0µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode0.6µs
1 MHz mode0.26µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode160nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CS_21TAA:SCLOutput Valid from Clock100 kHz mode3.45µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode0.9µs
1 MHz mode0.45µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode100nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
I2CS_23TBF:SDABus Free Time (2)100 kHz mode4.7µsVDD=3.3V, IPULLUP = 3mA, CLOAD=400pF
400 kHz mode1.3µs
1 MHz mode0.5µsVDD=3.3V, IPULLUP = 20mA, CLOAD=550pF
3.4 MHz mode160nsVDD=3.3V, IPULLUP = 20mA, CLOAD=100pF
Note:
  1. Longest delay between data hold timing based on bitfield SDAHOLD of register CTRLA from SERCOM Module and timing based on 4 period of GCLK_SERCOM for 100kHz/400kHz/1MHz mode.
  2. The amount of time the bus must be free before a new transmission can start (STOP condition to START condition).