31.7.11 Data

Note: This register is write-synchronized: SYNCBUSY.SYSOP must be checked to ensure that DATA register synchronization is complete.
Name: DATA
Offset: 0x28
Reset: 0x00
Property: Write-Synchronized

Bit 76543210 
 DATA[7:0] 
Access R/WR/WR/WR/WR/WR/WR/WR/W 
Reset 00000000 

Bits 7:0 – DATA[7:0] Data

The host data register I/O location (DATA) provides access to the host transmit and receive data buffers. Reading valid data or writing data to be transmitted can be performed successfully only when the host holds SCL low by the host (STATUS.CLKHOLD is set). An exception occurs when reading the last data byte after the STOP condition has been sent.

Accessing DATA.DATA automatically triggers I2C bus operations. The operation performed depends on the state of CTRLB.ACKACT, CTRLB.SMEN, and the type of access (read or write).