33.4.4 Sleep Mode Operation
The ADC can start conversions in Idle or Standby sleep mode if the Start Conversion bit field
in the Command register (COMMAND.START) is configured to start a conversion on an event
trigger. For Standby sleep mode, the Run in Standby bit in the Control A register
(CTRLA.RUNSTDBY) must also be ‘1’.
| Entering Power State | FREERUN | RUNSTDBY | DBGRUN | Behavior of Single or Series Conversion | Behavior of Burst Conversion |
|---|---|---|---|---|---|
| Standby | 0 | 0 | X | Finish the current conversion, then enter a sleep mode. No interrupt request is generated. The Series mode is aborted. | Finish the current burst without generating an interrupt request, then enter a sleep mode |
| 0 | 1 | X | Finish the current conversion, then enter a sleep mode. An interrupt request is generated. The Series mode is not aborted. | Finish the current burst, then enter a sleep mode, followed by an interrupt request | |
| 1 | 0 | X | Finish the current conversion, then enter a sleep mode. No interrupt request is generated. Not applicable in Series mode. | Finish the current burst without generating an interrupt request, then enter a sleep mode | |
| 1 | 1 | X |
Continuous free-running conversions with interrupt requests between conversions (relevant in Window mode). Not applicable in Series mode. | Continuous free-running bursts with interrupt requests between bursts (relevant in Window mode) | |
| Debug | 0 | X | 0 | Finish the ongoing conversion, then stop. New triggers are ignored. | Finish the current burst, then stop. New triggers are ignored. |
| 0 | X | 1 | Finish the ongoing conversion, then stop. New triggers are accepted. | Finish the current burst, then stop. New triggers are accepted. | |
| 1 | X | 0 | Finish the current conversion, then stop. The operation automatically restarts when the break is released. Not applicable in Series mode. | Finish the current burst, then stop. The operation automatically restarts when the break is released. | |
| 1 | X | 1 | Continuous free-running burst conversions, also active during break. Not applicable in Series mode. | Continuous free-running burst conversions, also active during break |
Refer to the PM - Power Manager chapter for more information about sleep mode operation.