31.6.1 Control A

Name: CTRLA
Offset: 0x00
Reset: 0x00000000
Property: PAC Write-Protection, Enable-Protected, Write-Synchronized

Bit 3130292827262524 
  LOWTOUTEN  SCLSM SPEED[1:0] 
Access R/WR/WR/WR/W 
Reset 0000 
Bit 2322212019181716 
 SEXTTOEN SDAHOLD[1:0]   PINOUT 
Access R/WR/WR/WR/W 
Reset 0000 
Bit 15141312111098 
          
Access  
Reset  
Bit 76543210 
 RUNSTDBY  MODE[2:0]ENABLESWRST 
Access R/WR/WR/WR/WR/WR/W 
Reset 000000 

Bit 30 – LOWTOUTEN SCL Low Time-Out

This bit enables the SCL low time-out. If SCL is held low for 25 ms to 35 ms, the client releases its clock hold, if enabled, and resets the internal state machine. Any interrupt flags set at the time of time-out will remain set.

Note: This bit is enable-protected. This bit is not synchronized.
ValueDescription
0Time-out disabled
1Time-out enabled

Bit 27 – SCLSM SCL Clock Stretch Mode

This bit controls when SCL is stretched for software interaction.

Note: This bit is enable-protected. This bit is not synchronized.
ValueDescription
0SCL is stretched according to Figure 31-9
1SCL is stretched only after the ACK bit, according to Figure 31-10

Bits 25:24 – SPEED[1:0] Transfer Speed

These bits define the bus speed.

Note: This bit field is enable-protected. This bit field is not synchronized.
ValueNameDescription
0x0SM_MODEStandard-mode (Sm) and Fast-mode (Fm)
0x1FASTPLUS_MODEFast-mode Plus (Fm+)
Other—Reserved

Bit 23 – SEXTTOEN Client SCL Low Extend Time-Out

This bit enables the client SCL low extend time-out. If SCL is cumulatively held low for more than 25 ms from the initial Start condition to a Stop condition, the client releases its clock hold, if enabled, and resets the internal state machine. Any interrupt flags set at the time of the timeout remain set. If the address was recognized, PREC is set when a Stop condition is received.

Note: This bit is enable-protected. This bit is not synchronized.
ValueDescription
0Time-out disabled
1Time-out enabled

Bits 21:20 – SDAHOLD[1:0] SDA Hold Time

These bits define the SDA hold time with respect to the falling edge of SCL.

Note: This bit field is enable-protected. This bit field is not synchronized.
ValueNameDescription
0x0DISDisabled
0x175NS50-100 ns hold time
0x2450NS300-600 ns hold time
0x3600NS400-800 ns hold time

Bit 16 – PINOUT Pin Usage

This bit configures the pin usage for either two-wire or four-wire operation.

Note: This bit is enable-protected. This bit is not synchronized.
ValueDescription
0Four-wire operation is disabled
1Four-wire operation is enabled

Bit 7 – RUNSTDBY Run in Standby

This bit defines the functionality during Standby sleep mode.

Note: This bit is enable-protected. This bit is not synchronized.
ValueDescription
0Disabled – All received data is dropped
1Wake on address match, if enabled

Bits 4:2 – MODE[2:0] Operating Mode

This bit field controls the SERCOM mode.

Note: This bit field is enable-protected. This bit field is not synchronized.
ValueNameDescription
0x0USART_EXTUSART with external clock
0x1USART_INTUSART with internal clock
0x2SPI_SLAVESPI Client mode
0x3SPI_MASTERSPI Host mode
0x4I2C_SLAVEI2C Client mode
0x5I2C_MASTERI2C Host mode

Bit 1 – ENABLE Enable

Note:
  1. This bit is write-synchronized: SYNCBUSY.ENABLE must be checked to ensure the CTRLA.ENABLE synchronization is complete.
  2. This bit is not enable-protected.
ValueDescription
0The peripheral is disabled or is being disabled
1The peripheral is enabled

Bit 0 – SWRST Software Reset

Writing ‘0’ to this bit has no effect.

Writing ‘1’ to this bit resets all SERCOM registers, except DBGCTRL, to their initial states, and disables the SERCOM.

Writing ‘1’ to CTRLA.SWRST always takes precedence, meaning that all other writes in the same write operation are discarded. Any register write access during an ongoing reset results in an APB error. Reading any register returns the register’s reset value.

Note:
  1. This bit is write-synchronized: SYNCBUSY.SWRST must be checked to ensure that the CTRLA.SWRST synchronization is complete.
  2. This bit is not enable-protected.
ValueDescription
0No reset operation is in progress
1The reset operation is in progress