28.4.2.1.1 Asynchronous Arithmetic Mode BAUD Value Selection

The formula given for fBAUD calculates the average frequency over 65,536 fref cycles. Although the BAUD register can be set to any value between 0 and 65,536, the actual average frequency of fBAUD over a single frame is more granular. BAUD register values that affect the average frequency over a single frame result in an integer increase in the cycles per frame (CPF).

CPF=freffBAUD(D+S)

Where:

  • D represents the number of data bits per frame
  • S represents the sum of the start bit and the first stop bit, if present

The following table shows the BAUD register value versus the baud frequency fBAUD at a serial engine frequency of 48 MHz. This assumes a D value of eight bits and an S value of two bits (ten bits total, including start and stop bits).

Table 28-2. BAUD Register Value vs. Baud Frequency
BAUD Register ValueSerial Engine CPFfBAUD at 48 MHz Serial Engine Frequency (fREF)
0–4061603 MHz
407–8081612.981 MHz
809–12051622.963 MHz
.........
652063177515.11 kHz
652073187115.06 kHz
652083196915.01 kHz