66.20.2 Timing Extraction

Figure 66-38. PDMIC Timing Diagram
Table 66-87. PDMIC IOSET1 Timings
SymbolPower Supply1.8V3.3VUnit
ParameterMinMaxMinMax
PDMIC0DATA setup time right3.53.5ns
PDMIC1DATA hold time right3.13.5ns
PDMIC2DATA setup time left3.53.5ns
PDMIC3DATA hold time left3.13.5ns
Table 66-88. PDMIC IOSET2 Timings
SymbolPower Supply1.8V3.3VUnit
ParameterMinMaxMinMax
PDMIC0DATA setup time right4.24.2ns
PDMIC1DATA hold time right22ns
PDMIC2DATA setup time left4.24.2ns
PDMIC3DATA hold time left22ns