66.13.2.2 Timing Extraction

Figure 66-12. FLEXCOM in SPI Host Modes 1 and 2
Figure 66-13. FLEXCOM in SPI Host Modes 0 and 3
Figure 66-14. FLEXCOM in SPI Client Modes 0 and 3
Figure 66-15. FLEXCOM in SPI Client Modes 1 and 2
Figure 66-16. FLEXCOM in SPI Client Mode - NPCS Timings
Table 66-53. FLEXCOM0 in SPI Mode IOSET1 Timings
Symbol Power Supply 1.8V 3.3V Unit
Parameter Min Max Min Max
Host Mode
SPI0 MISO Setup time before SPCK rises 14.3 12.8 ns
SPI1 MISO Hold time after SPCK rises 0 0 ns
SPI2 SPCK rising to MOSI 0 3.9 0 4.2 ns
SPI3 MISO Setup time before SPCK falls 14.7 13.4 ns
SPI4 MISO Hold time after SPCK falls 0 0 ns
SPI5 SPCK falling to MOSI 0 3.9 0 4.6 ns
Client Mode
SPI6 SPCK falling to MISO 10.9 13.4 9.1 11.9 ns
SPI7 MOSI Setup time before SPCK rises 5.3 5 ns
SPI8 MOSI Hold time after SPCK rises 0.4 0.3 ns
SPI9 SPCK rising to MISO 10.7 13.1 9 11.5 ns
SPI10 MOSI Setup time before SPCK falls 5.3 5 ns
SPI11 MOSI Hold time after SPCK falls 0.4 0.3 ns
SPI12 NPCS0 setup to SPCK rising 5.6 5.4 ns
SPI13 NPCS0 hold after SPCK falling 0.7 0.6 ns
SPI14 NPCS0 setup to SPCK falling 5.4 5.2 ns
SPI15 NPCS0 hold after SPCK rising 0.2 0.1 ns
SPI16 NPCS0 falling to MISO valid 17.5 16.2 ns
Table 66-54. FLEXCOM1 in SPI Mode IOSET1 Timings
Symbol Power Supply 1.8V 3.3V Unit
Parameter Min Max Min Max
Host Mode
SPI0 MISO Setup time before SPCK rises 15.7 13.8 ns
SPI1 MISO Hold time after SPCK rises 0 0 ns
SPI2 SPCK rising to MOSI 0 2.5 0 2.6 ns
SPI3 MISO Setup time before SPCK falls 15.2 13.9 ns
SPI4 MISO Hold time after SPCK falls 0 0 ns
SPI5 SPCK falling to MOSI 0 1.7 0 2.4 ns
Client Mode
SPI6 SPCK falling to MISO 11.4 13.7 9.4 12.3 ns
SPI7 MOSI Setup time before SPCK rises 2.4 2.1 ns
SPI8 MOSI Hold time after SPCK rises 1 0.9 ns
SPI9 SPCK rising to MISO 11 13.1 9 11.6 ns
SPI10 MOSI Setup time before SPCK falls 2.4 2.1 ns
SPI11 MOSI Hold time after SPCK falls 1 0.9 ns
SPI12 NPCS0 setup to SPCK rising 3.9 3.7 ns
SPI13 NPCS0 hold after SPCK falling 1.1 1 ns
SPI14 NPCS0 setup to SPCK falling 3.4 3.3 ns
SPI15 NPCS0 hold after SPCK rising 0.6 0.4 ns
SPI16 NPCS0 falling to MISO valid 16.8 15.5 ns
Table 66-55. FLEXCOM2 in SPI Mode IOSET1 Timings
Symbol Power Supply 1.8V 3.3V Unit
Parameter Min Max Min Max
Host Mode
SPI0 MISO Setup time before SPCK rises 15.3 13.4 ns
SPI1 MISO Hold time after SPCK rises 0 0 ns
SPI2 SPCK rising to MOSI 0 2.5 0 3 ns
SPI3 MISO Setup time before SPCK falls 15.6 13.7 ns
SPI4 MISO Hold time after SPCK falls 0 0 ns
SPI5 SPCK falling to MOSI 0 2.6 0 3.1 ns
Client Mode
SPI6 SPCK falling to MISO 11.7 13.5 9.4 11.7 ns
SPI7 MOSI Setup time before SPCK rises 2 1.6 ns
SPI8 MOSI Hold time after SPCK rises 0.5 0.5 ns
SPI9 SPCK rising to MISO 11.7 13.5 9.4 11.5 ns
SPI10 MOSI Setup time before SPCK falls 2 1.6 ns
SPI11 MOSI Hold time after SPCK falls 0.5 0.5 ns
SPI12 NPCS0 setup to SPCK rising 4 3.7 ns
SPI13 NPCS0 hold after SPCK falling 0.6 0.6 ns
SPI14 NPCS0 setup to SPCK falling 3.9 3.7 ns
SPI15 NPCS0 hold after SPCK rising 0.4 0.3 ns
SPI16 NPCS0 falling to MISO valid 16.8 13.6 ns
Table 66-56. FLEXCOM2 in SPI Mode IOSET2 Timings
Symbol Power Supply 1.8V 3.3V Unit
Parameter Min Max Min Max
Host Mode
SPI0 MISO Setup time before SPCK rises 13.3 11.2 ns
SPI1 MISO Hold time after SPCK rises 0 0 ns
SPI2 SPCK rising to MOSI 0 4.4 0 4.1 ns
SPI3 MISO Setup time before SPCK falls 4.3 12.5 ns
SPI4 MISO Hold time after SPCK falls 0 0 ns
SPI5 SPCK falling to MOSI 0.3 4.4 0.4 4.4 ns
Client Mode
SPI6 SPCK falling to MISO 10.1 12.2 8.2 10.4 ns
SPI7 MOSI Setup time before SPCK rises 3.3 3.1 ns
SPI8 MOSI Hold time after SPCK rises 0.8 0.7 ns
SPI9 SPCK rising to MISO 9.8 11.8 7.9 9.8 ns
SPI10 MOSI Setup time before SPCK falls 3.3 3.1 ns
SPI11 MOSI Hold time after SPCK falls 0.8 0.7 ns
SPI12 NPCS0 setup to SPCK rising 5.3 5.2 ns
SPI13 NPCS0 hold after SPCK falling 0.8 0.6 ns
SPI14 NPCS0 setup to SPCK falling 5 4.9 ns
SPI15 NPCS0 hold after SPCK rising 0.2 0.1 ns
SPI16 NPCS0 falling to MISO valid 15.9 14.2 ns
Table 66-57. FLEXCOM3 in SPI Mode IOSET1 Timings
Symbol Power Supply 1.8V 3.3V Unit
Parameter Min Max Min Max
Host Mode
SPI0 MISO Setup time before SPCK rises 14.6 12.7 ns
SPI1 MISO Hold time after SPCK rises 0 0 ns
SPI2 SPCK rising to MOSI 0 2.6 0 2.9 ns
SPI3 MISO Setup time before SPCK falls 14.2 13 ns
SPI4 MISO Hold time after SPCK falls 0 0 ns
SPI5 SPCK falling to MOSI 0 1.8 0 2.9 ns
Client Mode
SPI6 SPCK falling to MISO 11.6 14.1 9.5 12.7 ns
SPI7 MOSI Setup time before SPCK rises 3.3 3.2 ns
SPI8 MOSI Hold time after SPCK rises 0.9 0.7 ns
SPI9 SPCK rising to MISO 11.2 13.6 9.1 12.2 ns
SPI10 MOSI Setup time before SPCK falls 3.3 3.2 ns
SPI11 MOSI Hold time after SPCK falls 0.9 0.7 ns
SPI12 NPCS0 setup to SPCK rising 2.8 2.6 ns
SPI13 NPCS0 hold after SPCK falling 1.5 1.3 ns
SPI14 NPCS0 setup to SPCK falling 2.3 2.2 ns
SPI15 NPCS0 hold after SPCK rising 1 0.7 ns
SPI16 NPCS0 falling to MISO valid 15.4 14.1 ns
Table 66-58. FLEXCOM3 in SPI Mode IOSET2 Timings
Symbol Power Supply 1.8V 3.3V Unit
Parameter Min Max Min Max
Host Mode
SPI0 MISO Setup time before SPCK rises 14.1 12.6 ns
SPI1 MISO Hold time after SPCK rises 0 0 ns
SPI2 SPCK rising to MOSI 0 3.8 0 4.1 ns
SPI3 MISO Setup time before SPCK falls 14.9 13.7 ns
SPI4 MISO Hold time after SPCK falls 0 0 ns
SPI5 SPCK falling to MOSI 0 3.9 0 4.5 ns
Client Mode
SPI6 SPCK falling to MISO 10.6 13.1 8.6 11.8 ns
SPI7 MOSI Setup time before SPCK rises 3.7 3.5 ns
SPI8 MOSI Hold time after SPCK rises 0.6 0.5 ns
SPI9 SPCK rising to MISO 10.2 12.6 8.2 11.1 ns
SPI10 MOSI Setup time before SPCK falls 3.7 3.5 ns
SPI11 MOSI Hold time after SPCK falls 0.6 0.5 ns
SPI12 NPCS0 setup to SPCK rising 4.5 4.3 ns
SPI13 NPCS0 hold after SPCK falling 1 0.9 ns
SPI14 NPCS0 setup to SPCK falling 4 3.9 ns
SPI15 NPCS0 hold after SPCK rising 0.4 0.3 ns
SPI16 NPCS0 falling to MISO valid 16.9 15.6 ns
Table 66-59. FLEXCOM3 in SPI Mode IOSET3 Timings
Symbol Power Supply 1.8V 3.3V Unit
Parameter Min Max Min Max
Host Mode
SPI0 MISO Setup time before SPCK rises 14.2 12.7 ns
SPI1 MISO Hold time after SPCK rises 0 0 ns
SPI2 SPCK rising to MOSI 0 3.4 0 3.7 ns
SPI3 MISO Setup time before SPCK falls 15.1 13.8 ns
SPI4 MISO Hold time after SPCK falls 0 0 ns
SPI5 SPCK falling to MOSI 0 3.5 0 4.2 ns
Client Mode
SPI6 SPCK falling to MISO 11.4 14.1 9.4 12.8 ns
SPI7 MOSI Setup time before SPCK rises 5.4 5.1 ns
SPI8 MOSI Hold time after SPCK rises 0.4 0.3 ns
SPI9 SPCK rising to MISO 11 13.6 9 12.2 ns
SPI10 MOSI Setup time before SPCK falls 5.4 5.1 ns
SPI11 MOSI Hold time after SPCK falls 0.4 0.3 ns
SPI12 NPCS0 setup to SPCK rising 4.3 4.2 ns
SPI13 NPCS0 hold after SPCK falling 1.1 0.9 ns
SPI14 NPCS0 setup to SPCK falling 3.8 3.7 ns
SPI15 NPCS0 hold after SPCK rising 0.5 0.3 ns
SPI16 NPCS0 falling to MISO valid 17.5 16.2 ns
Table 66-60. FLEXCOM4 in SPI Mode IOSET1 Timings
Symbol Power Supply 1.8V 3.3V Unit
Parameter Min Max Min Max
Host Mode
SPI0 MISO Setup time before SPCK rises 14.7 13.1 ns
SPI1 MISO Hold time after SPCK rises 0 0 ns
SPI2 SPCK rising to MOSI 0 2.7 0 3.2 ns
SPI3 MISO Setup time before SPCK falls 15.2 13.8 ns
SPI4 MISO Hold time after SPCK falls 0 0 ns
SPI5 SPCK falling to MOSI 0 2.9 0 3.6 ns
Client Mode
SPI6 SPCK falling to MISO 10.9 13.2 8.9 11.9 ns
SPI7 MOSI Setup time before SPCK rises 3.3 3.2 ns
SPI8 MOSI Hold time after SPCK rises 0.7 0.6 ns
SPI9 SPCK rising to MISO 10.5 12.7 8.5 11.3 ns
SPI10 MOSI Setup time before SPCK falls 3.3 3.2 ns
SPI11 MOSI Hold time after SPCK falls 0.7 0.6 ns
SPI12 NPCS0 setup to SPCK rising 5.7 5.5 ns
SPI13 NPCS0 hold after SPCK falling 0.6 0.5 ns
SPI14 NPCS0 setup to SPCK falling 5.2 5 ns
SPI15 NPCS0 hold after SPCK rising 0 0 ns
SPI16 NPCS0 falling to MISO valid 17.8 16.5 ns
Table 66-61. FLEXCOM4 in SPI Mode IOSET2 Timings
Symbol Power Supply 1.8V 3.3V Unit
Parameter Min Max Min Max
Host Mode
SPI0 MISO Setup time before SPCK rises 14.7 11.5 ns
SPI1 MISO Hold time after SPCK rises 0 0 ns
SPI2 SPCK rising to MOSI 0 2.7 0 4.7 ns
SPI3 MISO Setup time before SPCK falls 15.2 12.8 ns
SPI4 MISO Hold time after SPCK falls 0 0 ns
SPI5 SPCK falling to MOSI 0 2.9 0.8 5.1 ns
Client Mode
SPI6 SPCK falling to MISO 10.9 13.2 7.8 10.2 ns
SPI7 MOSI Setup time before SPCK rises 3.3 2.2 ns
SPI8 MOSI Hold time after SPCK rises 0.7 0.8 ns
SPI9 SPCK rising to MISO 10.5 12.7 7.7 9.9 ns
SPI10 MOSI Setup time before SPCK falls 3.3 2.2 ns
SPI11 MOSI Hold time after SPCK falls 0.7 0.8 ns
SPI12 NPCS0 setup to SPCK rising 5.6 3.3 ns
SPI13 NPCS0 hold after SPCK falling 0.6 1.1 ns
SPI14 NPCS0 setup to SPCK falling 5.2 3.1 ns
SPI15 NPCS0 hold after SPCK rising 0 0.8 ns
SPI16 NPCS0 falling to MISO valid 17.8 12.9 ns
Table 66-62. FLEXCOM4 in SPI Mode IOSET3 Timings
Symbol Power Supply 1.8V 3.3V Unit
Parameter Min Max Min Max
Host Mode
SPI0 MISO Setup time before SPCK rises 14.2 12.2 ns
SPI1 MISO Hold time after SPCK rises 0 0 ns
SPI2 SPCK rising to MOSI 0 3.6 0 3.6 ns
SPI3 MISO Setup time before SPCK falls 15.1 13.3 ns
SPI4 MISO Hold time after SPCK falls 0 0 ns
SPI5 SPCK falling to MOSI 0.1 3.7 0.1 4 ns
Client Mode
SPI6 SPCK falling to MISO 9.9 12.4 8 10.5 ns
SPI7 MOSI Setup time before SPCK rises 3.9 3.7 ns
SPI8 MOSI Hold time after SPCK rises 0.8 0.7 ns
SPI9 SPCK rising to MISO 9.5 11.9 7.7 9.9 ns
SPI10 MOSI Setup time before SPCK falls 3.9 3.7 ns
SPI11 MOSI Hold time after SPCK falls 0.8 0.7 ns
SPI12 NPCS0 setup to SPCK rising 4.8 4.6 ns
SPI13 NPCS0 hold after SPCK falling 1 0.9 ns
SPI14 NPCS0 setup to SPCK falling 4.4 4.3 ns
SPI15 NPCS0 hold after SPCK rising 0.5 0.3 ns
SPI16 NPCS0 falling to MISO valid 16 14.2 ns
Figure 66-17. Minimum and Maximum Access Time for SPI Output Signal