3.2 Single Event Effects (SEE) Performance

This device has been characterized for SEE with heavy ions. The following SEE safe-operating area profile has been established using the ions, linear energy transfer (LET), range and total energy conditions shown.

Table 3-2. SEE Safe-Operating Area
Ion SpeciesEff. Surface LET (MeV·cm2/mg)ION Energy (MeV)Eff Range (μm)VDS(V)
VGS = 0VVGS = –5VVGS = –10VVGS = –15VVGS = –20V
Ag44 (±5%)1330 (±5%)117 (±5%)160160——150
Xe63.9 (±5%)946 (±5%)70 (±7.5%)150150150150—
Au90.0 (±5%)1490 (±5%)83 (±5%)125125———
Figure 3-1. SEE Safe-Operating Area

Microchip Radiation-Hardened MOSFETs are tested in a manner to provide maximum observability during heavy ion exposure. The filtering circuits of MIL-STD-750F Method 1080 are not used.

A VGS/VDS point is accepted on the prior plot if all of the following conditions are met:

1. A fluence of 3x105 ± 20% ions/cm2 is delivered to each sample.

2. No Single-Event Burnout is detected via continuous monitoring of the drain current.

3. No Single-Event Gate Rupture is detected via continuous monitoring of the gate current.

4. Post-Exposure IDSS tests continue to pass specification.

5. Post-Exposure IGSS tests continue to pass specification.