7.1 Theory of Operation
The block diagram illustrates the control loop of the MCP16080A/B. The output voltage is sensed by the MCP16080A/B feedback pin via the voltage of the external resistive divider RTOP, RBOT and compared to a 1.2V reference voltage at the PWM comparator through a low gain transconductance (gm) amplifier. If the VFB voltage drops below 1.2V, the PWM comparator will trigger the control logic and turn ON the high-side MOSFET to generate an On-Time period.
At the end of the On-Time period, the internal high-side MOSFET turns OFF and the low-side MOSFET turns ON. The Off-Time period length depends upon the feedback voltage. If the Off-Time period determined by the feedback voltage is less than the minimum Off-Time, which is about 185 ns, then the MCP16080A/B control logic will apply the minimum Off-Time instead. The minimum period is required to maintain enough energy in the bootstrap capacitor (CBST) to drive the high-side MOSFET.
Figure 7-1 shows the control loop timing for the MCP16080A/B during steady-state operation. During steady-state, the gm amplifier senses the feedback voltage ripple, which is proportional to the output voltage ripple and the inductor current ripple (if the ESR of the output capacitor is large enough), to trigger the On-Time period. The termination of the Off-Time is controlled by the feedback voltage as well. At the valley of the feedback voltage ripple, which occurs when VFB falls below VREF, the tOFF ends, and the next tON is triggered through the control logic circuitry.
In order to meet the stability requirements, the MCP16080A/B feedback voltage ripple should be in phase with the inductor current ripple and large enough to be sensed by the gm amplifier. The recommended feedback voltage ripple is 50 mV ~ 200 mV. If a low-ESR output capacitor is selected, the feedback voltage ripple may be too small to be sensed by the gm amplifier and the PWM comparator. Additionally, the output voltage ripple and the feedback voltage ripple are not necessarily in phase with the inductor current ripple if the ESR of the output capacitor is very low. For these applications, ripple injection is required to ensure proper operation. Refer to the Ripple Injection section under the Application Information chapter for details about the ripple injection technique.
The switching frequency changes during load transients, but returns to the nominal fixed frequency once the output has stabilized at the new load current level. With the varying duty cycle and switching frequency, the output recovery time is fast and the output voltage deviation is small for the MCP16080A/B switching regulator.