6 Typical Performance Curves

Note:
  • The graphs and tables provided following this note are a statistical summary based on a limited number of samples and are provided for informational purposes only. The performance characteristics listed herein are not tested or guaranteed. In some graphs or tables, the data presented may be outside the specified operating range (e.g., outside specified power supply range) and, therefore, outside the warranted range.
  • Unless otherwise indicated, TJ = +25°C, VIN = VEN/UVLO = 48V, VOUT = 12V, IOUT = 500 mA, RON = 97.6 kΩ, L = 100 µH, CIN = 10 µF X7R Ceramic Capacitor, COUT = 4 x 10 µF X7R Ceramic Capacitors.
Figure 6-1. 3.3V VOUT Efficiency vs. IOUT
Figure 6-2. 3.3V VOUT vs. IOUT
Figure 6-3. 5V VOUT Efficiency vs. IOUT
Figure 6-4. 5V VOUT vs. IOUT
Figure 6-5. 12V VOUT Efficiency vs. IOUT
Figure 6-6. 12V VOUT vs. IOUT
Figure 6-7. 24V VOUT Efficiency vs. IOUT
Figure 6-8. 24V VOUT vs. IOUT
Figure 6-9. Switch RDSON vs. Temperature
Figure 6-10. VOUT vs. VIN
Figure 6-11. Overcurrent Hard Stop vs. Temperature
Figure 6-12. VFB vs. Temperature
Figure 6-13. Undervoltage Lockout vs. Temperature
Figure 6-14. Quiescent Shutdown Current vs. VIN
Figure 6-15. No Load Input Current vs. VIN, MCP16080A
Figure 6-16. Quiescent Stand-by Current vs. VIN
Figure 6-17. No Load Input Current vs. VIN, MCP16080B
Figure 6-18. Quiescent Sleep Current vs. VIN
Figure 6-19. HyperLight Load to DCM Threshold vs. VIN
Figure 6-20. On-Time vs. VIN vs. RON
Figure 6-21. Light Load Switching Waveforms – MCP16080A
Figure 6-22. Start-Up From VIN – MCP16080B
Figure 6-23. Light Load Switching Waveforms – MCP16080B
Figure 6-24. Start-Up from EN/UVLO – MCP16080B
Figure 6-25. Heavy Load Switching Waveforms – MCP16080B
Figure 6-26. Pre-bias Start-Up With EN/UVLO – MCP16080A
Figure 6-27. Load Transient Response (10 mA to 500 mA) – MCP16080A
Figure 6-28. Load Transient Response (200 mA to 800 mA) – MCP16080A
Figure 6-29. HyperLight Load to CCM Transition – MCP16080A
Figure 6-30. Line Transient Response – MCP16080B
Figure 6-31. Short-Circuit Applied – MCP16080B
Figure 6-32. Short-Circuit Recovery – MCP16080B
Figure 6-33. Short-Circuit and Recovery – MCP16080B