1.1.1 The ADC Operates at Half of the Specified Speed

The minimum ADC Clock Period (TAD) is specified as 1 μs in the device data sheet; however, the actual minimum TAD is 2 μs.

Work around

None.

Affected Silicon Revisions

A2A3A4
X