| Periodic Interrupt mode | Set when the counter reaches TOP | CCMP | CNT == TOP |
| Timeout Check mode | Set when the counter reaches TOP |
| Single-Shot mode | Set when the counter reaches TOP |
| Input Capture Frequency Measurement mode | Set on edge when the Capture register is loaded
and the counter restarts; the flag clears when the capture is
read | -- | On Event, copy CNT to CCMP, and restart counting
(CNT == BOTTOM) |
| Input Capture on Event mode | Set when an event occurs and the Capture
register is loaded; the flag clears when the capture is
read | On Event, copy CNT to CCMP, and
continue counting |
| Input Capture Pulse-Width Measurement
mode | Set on edge when the Capture register is loaded;
the previous edge initialized the count; the flag clears when
the capture is read |
| Input Capture Frequency and Pulse-Width
Measurement mode | Set on the second edge (positive or negative)
when the counter is stopped; the flag clears when the capture is
read |
| 8-Bit PWM mode | Set when the counter reaches CCML | CCML | CNT == CCML |