17.1 Dynamic detection intrusion (PIOBU) alarm issue
The error counter fails to reinitialize after a dynamic detection intrusion (PIOBU) alarm.
Work Around
None
Affected Device Revisions
A0 | A1 | A1-D1G | A1-D2G | A1-D4G | |||
X | X | X | X | X |
The error counter fails to reinitialize after a dynamic detection intrusion (PIOBU) alarm.
None
A0 | A1 | A1-D1G | A1-D2G | A1-D4G | |||
X | X | X | X | X |