12.5 Temperature sensor spurious activation with CH30

Enabling ADC channel 30 enables the temperature sensor.

Work Around

To stop the temperature sensor and save its power consumption, perform a conversion prior to writing ADC_TEMPMR.TEMPON=0.

Affected Device Revisions

A0A1A1-D1GA1-D2GA1-D4G
XXXXX