When an incorrect DMTPRECLR.STEP1 value is detected, this bit is set. It is cleared by a Reset.
Bit 6 – BAD2
When an incorrect value of DMTCLR.STEP2 is detected, this bit is set. It is cleared by a Reset.
Bit 5 – DMT_EVENT
This bit is set when the Deadman timer event is detected (counter expired or bad STEP1[7:0] or STEP2[7:0] value is entered prior to the counter increment). This bit remains set and is cleared only by a Reset.
Bit 0 – WINOPN Deadman Timer Clear Window bit.
A value of ‘1’ indicates that a STEP2 clear action can take place, and if this clearing action occurs as part of a correct sequence of actions, the DMT counter will be cleared.
DS00005998F
The online versions of the documents are provided as a courtesy. Verify all content and data in the device’s PDF documentation found on the device product page.