This register is
write-restricted and only writable if bit fields CCCR.CCE bit (CCCR <1>) = 1 and
CCCR.INIT bit (CCCR <0>) = 1.
Table 43-46. Register Bit Attribute Legend
Symbol
Description
Symbol
Description
Symbol
Description
R
Readable bit
HC
Cleared by Hardware
(Grey cell)
Unimplemented
W
Writable bit
HS
Set by Hardware
X
Bit is unknown at Reset
K
Write to clear
S
Software settable bit
—
—
Name:
RXBC
Offset:
0xAC
Reset:
0x00000000
Property:
Write-restricted
Bit
31
30
29
28
27
26
25
24
Access
Reset
Bit
23
22
21
20
19
18
17
16
Access
Reset
Bit
15
14
13
12
11
10
9
8
RBSA[15:8]
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
Bit
7
6
5
4
3
2
1
0
RBSA[7:0]
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
Bits 15:0 – RBSA[15:0] Rx Buffer Start
Address
Configures the start
address of the Rx Buffers section in the Message RAM. Also used to reference debug
message A,B,C. When the CAN module addresses the Message RAM it addresses 32-bit
words, not single bytes. The configurable start addresses are 32-bit word addresses,
i.e. only bits 15 to 2 are evaluated, the two least significant bits are ignored.