49.16 FRC AC Electrical Specifications

Table 49-17. FRC AC Electrical Specifications
AC CharacteristicsStandard Operating Conditions: VDD33 = VDDIO = AVDD = 1.9–3.6V (Unless Otherwise Stated)

Operating Temperature:

-40°C ≤ TA ≤ +125°C for Extended Temperature

Parameter NumberSymbolCharacteristicsMin.Typ.Max.UnitsConditions
FRC1FINTFREQInternal FRC Frequency—8—MHz—
FRC3TSUFRCStart-up time of internal FRC—1215µs—
FRC5FACCUFRC Accuracy-2±0.92%—
FRC7DUTY_CYCLEFRC Duty Cycle—50—%—
FRC9C_USEFRC User Tune-1.9—1.9%Maximum Frequency drift possible by using the Frequency trim bits (OSCTRIM register)