31.6.6 Status
| Name: | STATUS |
| Offset: | 0x1A |
| Reset: | 0x0000 |
| Property: | – |
| Bit | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | |
| SEXTTOUT | |||||||||
| Access | R/W | ||||||||
| Reset | 0 |
| Bit | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |
| CLKHOLD | LOWTOUT | SR | DIR | RXNACK | COLL | BUSERR | |||
| Access | R | R/W | R | R | R | R/W | R/W | ||
| Reset | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Bit 9 – SEXTTOUT Client SCL Low Extend Time-Out
This bit is set if a client SCL low extend timeout occurs.
This bit is cleared automatically when responding to a new START condition
with ACK or NACK (write 0x3 to CTRLB.CMD).
This bit is not cleared when INTFLAG.AMATCH is cleared. Write '1' to clear the
SEXTTOUT status bit.
Writing a ‘0’ to this bit has no effect.
Writing a ‘1’ to this bit clears the status.
| Value | Description |
|---|---|
| 0 | No SCL low extend timeout has occurred |
| 1 | An SCL low extend timeout has occurred |
Bit 7 – CLKHOLD Clock Hold
The client Clock Hold bit (STATUS.CLKHOLD) is set when the client holds the SCL line low to stretch the I2C clock. Software must treat this bit as a read-only status flag that is set when INTFLAG.DRDY or INTFLAG.AMATCH is set. Do not clear the STATUS.CLKHOLD bit, as doing so may alter the current clock hold state.
This bit is automatically cleared when the corresponding interrupt flag is cleared.
Bit 6 – LOWTOUT SCL Low Time-out
This bit is set if an SCL low time-out occurs.
This bit is cleared automatically when responding to a new start condition
with ACK or NACK (write 0x3 to CTRLB.CMD). This bit is not cleared when
INTFLAG.AMATCH is cleared. Write '1' to clear the LOWTOUT status bit.
Writing a ‘0’ to this bit has no effect.
Writing a ‘1’ to this bit clears the status.
| Value | Description |
|---|---|
| 0 | No SCL low timeout has occurred |
| 1 | An SCL low timeout has occurred |
Bit 4 – SR Repeated Start
When INTFLAG.AMATCH is raised due to an address match, SR indicates whether a repeated START or START condition has occurred.
This flag is valid only while INTFLAG.AMATCH is set.
| Value | Description |
|---|---|
| 0 | A START condition occurred on last address match |
| 1 | A repeated START condition occurred on last address match |
Bit 3 – DIR Read/Write Direction
The Read/Write Direction (STATUS.DIR) bit stores the direction of the last address packet received from the host.
| Value | Description |
|---|---|
| 0 | A host write operation is in progress |
| 1 | A host read operation is in progress |
Bit 2 – RXNACK Received Not Acknowledge
This bit indicates whether the last data packet sent was acknowledged.
| Value | Description |
|---|---|
| 0 | The host responded with an ACK |
| 1 | The host responded with a NACK |
Bit 1 – COLL Transmit Collision
If set, the I2C client was unable to transmit a high data or NACK bit. The I2C client immediately releases the SDA and SCL lines and waits for the next packet addressed to it.
This flag is intended for the SMBus Address Resolution Protocol (ARP). A detected collision in non-ARP situations indicates a protocol violation and must be treated as a bus error.
Note that this status does not trigger any interrupt and must be checked by
software to verify that the data were sent correctly. This bit is cleared automatically
when responding to an address match with an ACK or a NACK (writing 0x3 to
CTRLB.CMD). This bit is not cleared when INTFLAG.AMATCH is cleared. Write
'1' to clear the COLL status bit.
Writing a ‘0’ to this bit has no effect.
Writing a ‘1’ to this bit clears the status.
| Value | Description |
|---|---|
| 0 | No collision was detected on the last data byte sent |
| 1 | A collision was detected on the last data byte sent |
Bit 0 – BUSERR Bus Error
The Bus Error bit (STATUS.BUSERR) indicates that an illegal bus condition has occurred, regardless of bus ownership. An illegal bus condition is detected if a protocol violating START, repeated START, or Stop condition occurs on the I2C bus lines. A START condition directly followed by a STOP condition is one example of a protocol violation. A timeout occuring during a frame is also considered a protocol violation and sets STATUS.BUSERR.
This bit is cleared automatically when responding to an address match with
an ACK or a NACK (writing 0x3 to CTRLB.CMD). This bit is not cleared when
INTFLAG.AMATCH is cleared. Write '1' to clear the BUSERR status bit.
Writing a ‘0’ to this bit has no effect.
Writing a ‘1’ to this bit clears
the status.
| Value | Description |
|---|---|
| 0 | No bus error was detected |
| 1 | A bus error was detected |