16.5.3 User Channel MUX

Each event user can be connected to one channel and several users can be connected to the same channel. The following table lists all Event System users with their corresponding user ID number and name. The user name is given by combining USER with Peripheral and Input from the table below in the following way: USERPERIPHERALINPUT.

USERAsync/SyncDescription
#Name
PeripheralInput
0CCLLUT0AAsyncCCL LUT0 event input A
1LUT0BCCL LUT0 event input B
2LUT1ACCL LUT1 event input A
3LUT1BCCL LUT1 event input B
4LUT2ACCL LUT2 event input A
5LUT2BCCL LUT2 event input B
6LUT3A(1)CCL LUT3 event input A
7LUT3B(1)CCL LUT3 event input B
8ADC0STARTAsyncADC start on event
9EVSYSEVOUTA-EVSYS pin output A
10EVOUTB(1)EVSYS pin output B
11EVOUTCEVSYS pin output C
12EVOUTDEVSYS pin output D
13EVOUTE(1)EVSYS pin output E
14EVOUTF(1)EVSYS pin output F
15USART0IRDASyncUSART0 IrDA event input
16USART1IRDAUSART1 IrDA event input
17USART2(1)IRDAUSART2 IrDA event input
18TCA0CNTASyncCount on positive event edge
Count on any event edge
Count while event signal is high
Event level controls count direction
19CNTBSyncEvent level controls count direction
Restart counter on any event edge
Restart counter on any event edge
Restart counter while event signal is high
20TCA1(1)CNTASyncCount on positive event edge
Count on any event edge
Count while event signal is high
Event level controls count direction
21CNTBSyncEvent level controls count direction
Restart counter on positive event edge
Restart counter on any event edge
Restart counter while event signal is high
22TCB0CAPTSyncTimeout check
Input capture on event
Input capture frequency measurement
Input capture pulse-width Measurement
Input capture frequency and pulse width measurement
BothSingle shot
23COUNTSyncCount on event
24TCB1CAPTSyncTimeout check
Input capture on event
Input capture frequency measurement
Input capture pulse-width Measurement
Input capture frequency and pulse width measurement
BothSingle shot
25COUNTSyncCount on event
26TCB2CAPTSyncTimeout check
Input capture on event
Input capture frequency measurement
Input capture pulse-width Measurement
Input capture frequency and pulse width measurement
BothSingle shot
27COUNTSyncCount on event
28TCB3(1)CAPTSyncTimeout check
Input capture on event
Input capture frequency measurement
Input capture pulse-width Measurement
Input capture frequency and pulse width measurement
BothSingle shot
29COUNTSyncCount on event
Note:
  1. Not all peripheral instances are available for all pin counts. Refer to the Peripherals and Architecture section for details.
Name: USER
Offset: 0x20 + n*0x01 [n=0..29]
Reset: 0x00
Property: -

Bit 76543210 
 USER[7:0] 
Access R/WR/WR/WR/WR/WR/WR/WR/W 
Reset 00000000 

Bits 7:0 – USER[7:0] User Channel Selection

Configures which Event System channel the user is connected to.
ValueDescription
0OFF, no channel is connected to this Event System user
nThe event user is connected to CHANNEL(n-1)