40.7.22 ADACT

ADC Auto Conversion Trigger Source Selection Register
Name: ADACT
Address: 0x3F9

Bit 76543210 
   ACT[5:0] 
Access R/WR/WR/WR/WR/WR/W 
Reset 000000 

Bits 5:0 – ACT[5:0] Auto-Conversion Trigger Select

ACT Auto-conversioin Trigger Source
111111 Software write to ADPCH
111110 Software read of ADRESH
111101 Software read of ADERRH
111100-101000 Reserved
100111 CLC8_OUT
100110 CLC7_OUT
100101 CLC6_OUT
100100 CLC5_OUT
100011 CLC4_OUT
100010 CLC3_OUT
100001 CLC2_OUT
100000 CLC1_OUT
011111 Interrupt-on-change Interrupt Flag
011110 CMP2_OUT
011101 CMP1_OUT
011100 NCO3_OUT
011011 NCO2_OUT
011010 NCO1_OUT
011001-011000 Reserved
010111 PWM3S1P2_OUT
010110 PWM3S1P1_OUT
010101 PWM2S1P2_OUT
010100 PWM2S1P1_OUT
010011 PWM1S1P2_OUT
010010 PWM1S1P1_OUT
010001 CCP3_trigger
010000 CCP2_trigger
001111 CCP1_trigger
001110 SMT1_overflow
001101-001001 Reserved
001000 TMR6_postscaled
000111 TMR5_overflow
000110 TMR4_postscaled
000101 TMR3_overflow
000100 TMR2_postscaled
000011 TMR1_overflow
000010 TMR0_overflow
000001 Pin selected by ADACTPPS
000000 External Trigger Disabled