7.7 Active Mode

The device is in Active mode when the UVLO rising threshold on the EN/UVLO pin is reached. In this mode of operation, all blocks are active and the switching operation is enabled.

The MCP16080A has a current consumption of 45 µA, while the MCP16080B has a current consumption of 6.2 mA when running in Active mode.