7.6 Soft Start

The Soft Start feature reduces the power supply input surge current at start-up by controlling the output voltage rise time. The input surge appears while the output capacitor is charged up. A slower output rise time will draw a lower input surge current.

The MCP16080A/B implements an internal digital soft-start by generating the ramp from 0 to 100% in approximately 2.5 ms. Therefore, the output voltage is controlled to increase slowly with a staircase VFB ramp. Once the soft-start cycle ends, the related circuitry is disabled to reduce current consumption.