7.14 Zero Crossing Detection
The MCP16080A has a zero-crossing comparator that monitors the negative inductor current by sensing the voltage drop across the low-side MOSFET during its On-Time. When the MCP16080A detects zero crossing, the low-side turns OFF, therefore activating the DCM operation.
Additionally, to avoid triggering this during switching transitions, a blanking time of 100 ns is used.