7.13 Negative Overcurrent Limit

The MCP16080B features a negative current limit protection by sensing the SW voltage when the low-side MOSFET is ON. This prevents excessive current levels in the power train.

If the SW node voltage exceeds 175 mV, typical, or an equivalent of –500 mA while the low-side MOSFET is conducting, the device turns OFF the low-side MOSFET and the inductor current is pushed to the input through the body diode of the high-side MOSFET until the current in the inductor drops to zero.

This feature is mainly intended to protect the device in some particular transient conditions (such as a large load step associated with an extremely large capacitive load). This protection should never be exercised continuously and/or without a large input bulk capacitor, because it may quickly destroy the device. When this protection is engaged, energy is pumped back from the output into the input source. If the input supply has no sinking capability and/or the input bulk decoupling capacitance is not large enough, the input voltage will rise to the point where the device becomes permanently damaged.