7.11 Forced Continuous Conduction Mode (FCCM)

The MCP16080B always operates in Forced Continuous Conduction mode, meaning that the transient response is improved but the efficiency at light loads is reduced. In addition, the output voltage ripple is lower when compared to the ripple of the devices featuring HLL operation.