7.12 Hiccup Operation and Cycle-by-Cycle Current Limit

The MCP16080A/B integrates cycle-by-cycle current limiting and hiccup-mode overcurrent protection to protect the power stage during sustained overload or short-circuit conditions.

Overcurrent detection is performed by sensing the voltage drop across the RDS(ON) of the internal high-side power MOSFET. This eliminates the need for an external current-sense resistor, reducing cost, PCB area, and additional power losses. During each switching cycle, the inductor peak current is monitored through the high-side MOSFET during the On-Time. A 35 ns blanking time is applied before the current-sense signal is used, improving noise immunity.

The device implements two distinct current thresholds, as illustrated in Figure 7-2:

  • Hiccup current limit: 1.4 A typical
  • Hard-stop/cycle-by-cycle current limit: 1.8 A typical

During normal switching operation, the switch-node voltage VSW toggles approximately between VIN and 0V. The inductor current IL ramps up during the On-Time and ramps down during the Off-Time. If the peak inductor current exceeds the hiccup current limit over multiple consecutive switching cycles, the device identifies a sustained overcurrent condition.

The hiccup protection uses a digital counter to track continuous overcurrent events. When 16 consecutive overcurrent pulses are detected, the switching pulses are stopped, and the device enters a cooldown interval before attempting restart, typically after 1.3 ms. This mechanism is optimized for typical operating pulse widths and switching frequencies (48V input voltage, 12V output voltage, and 350 kHz switching frequency). The overcurrent counter is reset if either 16 consecutive non-overcurrent pulses are detected or the fixed 1.3 ms timer expires. There are a total of three counters integrated into the device: one for overcurrent events, one for non-overcurrent events and one for the fixed rest time. This prevents false entry into hiccup mode during fast transient events.

The cycle-by-cycle current limit provides fast protection during overload or short-circuit conditions. When the peak high-side MOSFET current reaches the hard-stop threshold, the high-side MOSFET is turned OFF immediately for that switching cycle, and the low-side MOSFET is turned ON. The low-side MOSFET remains active until the programmed On-Time (tON) expires, plus an additional shutdown delay of 310 ns, allowing the inductor current to decay and effectively limit the current.

If the inductor current remains above the hiccup threshold but below the cycle-by-cycle hard-stop limit, the hiccup timing condition can still be met. Because overcurrent hiccup mode is triggered whenever a hard-stop event occurs, repeated or sustained overcurrent conditions cause the device to restart in hiccup operation. This sequence continues until the overload or short-circuit condition is removed.

Depending on the hardware configuration and operating conditions, such as start-up, transient operation, or high VIN/VOUT ratio, the hiccup current limit and hard-stop current limit may trigger nearly concurrently. This can occur due to inductance variation with current and different delays in the two current-limitation loops, potentially resulting in more than 16 switching pulses before restart occurs.

For applications with a high step-down ratio, the switching frequency should be selected low enough to avoid operation at the minimum On-Time limit. Overall, the MCP16080A/B remains protected under short-circuit conditions through the combined action of cycle-by-cycle overcurrent protection, hiccup mode and thermal shutdown.

Figure 7-2. Cycle-by-Cycle Current Limit and Hiccup Operation