5.2 Troubleshooting Steps

The following table lists the problem and resolution sequence to assist in troubleshooting of minor operating problems. If the following steps do not solve your problem, contact your local dealer for further assistance.
Table 5-1. Troubleshooting Steps
ProblemCorrective Steps
Midspan does not power-up
  1. Verify a reliable power cord is used.
  2. Make sure that the power cord is properly connected.
  3. Verify that the voltage at power inlet is between 100 VAC–240 VAC.
  4. Remove and reapply power to the device during power-up sequence.
PD does not operate
  1. Verify that the port is enabled (midspan did not detect a PD).
  2. Verify that the PD is designed for PoE operation.
  3. Verify that you are using a standard Category 5/5e/6, straight-wired cable, with four-pairs according to data rate.
  4. If an external power splitter is in use, replace it with a viable splitter.
  5. Verify that the Data source is connected to the Data In port.
  6. Verify that the PD is connected to the Data and Power Output port.
  7. Verify that there is no short over any of the twisted-pair cables or over the RJ45 connectors.

End device operates, but there is no data link.

  1. If an external power splitter is in use, replace it with a viable splitter.
  2. Verify that for this link you are using a standard UTP/FTP Category 5 straight (non-crossover) cabling, with all four pairs.
  3. Verify that the Ethernet cable length is less than 100 meters from Ethernet source to the remote terminal.