2.3.1 Missing Codes with Internal Reference

When ADC is using internal reference and running in active or idle sleep mode, the ADC will have missing codes.

Work Around

Use external reference or perform conversions only when device is in standby sleep mode.

Affected Silicon Revisions

Rev. A0
X