3.4.2 Power-Down Specification Limit (TA = -40°C to 85°C)
A clarification for the power-down specification limit has been made. This clarification has corrections that are impractical to mark in bold. The following tables in this section contain the most current information and notes.
| Symbol | Parameter | Condition | Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|---|
| ICC | Power supply current(1) | Active 1 MHz, VCC = 2V | 0.5 | 0.75 | mA | |
| Active 4 MHz, VCC = 3V | 2.6 | 3.5 | ||||
| Active 8 MHz, VCC = 5V | 9.0 | 12.0 | ||||
| Idle 1 MHz, VCC = 2V | 0.14 | 0.25 | ||||
| Idle 4 MHz, VCC = 3V | 0.75 | 1.5 | ||||
| Idle 8 MHz, VCC = 5V | 2.9 | 5.0 | ||||
| Power-save mode(2) | 32.768 kHz TOSC enabled, VCC = 1.8V | 0.75 | µA | |||
| 32.768 kHz TOSC enabled, VCC = 3V | 1.0 | |||||
| Power-down mode(2) | WDT enabled, VCC = 3V | 6.7 | 15.0 | |||
| WDT disabled, VCC = 3V | 0.2 | 2.0 |
Note:
- All bits are set in the ‘Power Reduction Register’ on page 43.
- Maximum and Typical values for 25°C. Maximum values are test limits in production.
| Symbol | Parameter | Condition | Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|---|
| ICC | Power supply current(1) | Active 1 MHz, VCC = 2V | 0.5 | 0.75 | mA | |
| Active 4 MHz, VCC = 3V | 2.6 | 3.5 | ||||
| Active 8 MHz, VCC = 5V | 9.0 | 12.0 | ||||
| Idle 1 MHz, VCC = 2V | 0.14 | 0.25 | ||||
| Idle 4 MHz, VCC = 3V | 0.75 | 1.5 | ||||
| Idle 8 MHz, VCC = 5V | 2.9 | 5.0 | ||||
| Power-save mode(2) | 32.768 kHz TOSC enabled, VCC = 1.8V | 0.75 | µA | |||
| 32.768 kHz TOSC enabled, VCC = 3V | 1.0 | |||||
| Power-down mode(2) | WDT enabled, VCC = 3V | 6.7 | 15.0 | |||
| WDT disabled, VCC = 3V | 0.2 | 2.0 |
Note:
- All bits are set in the ‘Power Reduction Register’ on page 43.
- Maximum and Typical values for 25°C. Maximum values are test limits in production.