42.1 Output Voltage Selection
The DAC has 210 voltage level ranges. Each level is determined by the DACxDAT register. The DAC output voltage can be determined by using Equation 42-1.
DACx_output= ((VREF+−VREF−)×DACR2n)+VREF−
The DAC has 210 voltage level ranges. Each level is determined by the DACxDAT register. The DAC output voltage can be determined by using Equation 42-1.
The online versions of the documents are provided as a courtesy. Verify all content and data in the device’s PDF documentation found on the device product page.