42.1 Output Voltage Selection

The DAC has 210 voltage level ranges. Each level is determined by the DACxDAT register. The DAC output voltage can be determined by using Equation 42-1.

Equation 42-1. DAC Output Equation
DACx_output=((VREF+VREF)×DACR2n)+VREF