4.7 Initialization Summary
- Enable the ADC GCLK with the appropriate source
clock and dividers to reach the required sampling frequency.
- Set ADC_TEMPMR.TEMPON and wait for the specified
start-up time.
- Set ADC_MR.STARTUP to SUT512.
- Set ADC_MR.TRACKTIM to 6 and ADC_EMR.TRACKX to
1.
- Clear ADC_CCR.DIFF15.
- Set ADC_TRGR.TRGMOD to the appropriate value.
- Set ADC_EMR.OSR to OSR256.
- Set ADC_EMR.ADCMODE to NORMAL.
- Set ADC_EMR.SIGNMODE to SE_UNSG_DF_SIGN.
- Set the single-ended measurement on VBG channel
31: ADC_ACR.SRCLCH = 1.
- Set the single-ended measurement on
VTEMP channel 31: ADC_ACR.SRCLCH = 0.