29.8.8 Event User m

Name: USERm
Offset: 0x80 + m*0x04 [m=0..30]
Reset: 0x00000000
Property: PAC Write-Protection

Bit 3130292827262524 
          
Access  
Reset  
Bit 2322212019181716 
          
Access  
Reset  
Bit 15141312111098 
          
Access  
Reset  
Bit 76543210 
     CHANNEL[3:0] 
Access R/WR/WR/WR/W 
Reset 0000 

Bits 3:0 – CHANNEL[3:0] Channel Event Selection

These bits are used to select the channel to connect to the event user.

Note that to select channel m, the value (m+1) must be written to the USER.CHANNEL bit group.

Value Channel Number
0x00 No channel output selected
0x01 0
0x02 1
0x03 2
0x04 3
0x05 4
0x06 5
0x07 6
0x08 7
0x09-0xFF Reserved
Table 29-2. User Multiplexer Number
USERm User Multiplexer Description Path Type
m = 0 RTC TAMPEVT Tamper Event Asynchronous, synchronous, and resynchronized paths
m = 1 PORT EV0 Event 0 Asynchronous, synchronous, and resynchronized paths
m = 2 PORT EV1 Event 1 Asynchronous, synchronous, and resynchronized paths
m = 3 PORT EV2 Event 2 Asynchronous, synchronous, and resynchronized paths
m = 4 PORT EV3 Event 3 Asynchronous, synchronous, and resynchronized paths
m = 5 DMAC CH0 Channel 0 Synchronous, and resynchronized paths
m = 6 DMAC CH1 Channel 1 Synchronous, and resynchronized paths
m = 7 DMAC CH2 Channel 2 Synchronous, and resynchronized paths
m = 8 DMAC CH3 Channel 3 Synchronous, and resynchronized paths
m = 9 TCC0 EV0 - Asynchronous, synchronous, and resynchronized paths
m = 10 TCC0 EV1 - Asynchronous, synchronous, and resynchronized paths
m = 11 TCC0 MC0 Match/Capture 0 Asynchronous, synchronous, and resynchronized paths
m = 12 TCC0 MC1 Match/Capture 1 Asynchronous, synchronous, and resynchronized paths
m = 13 TCC0 MC2 Match/Capture 2 Asynchronous, synchronous, and resynchronized paths
m = 14 TCC0 MC3 Match/Capture 3 Asynchronous, synchronous, and resynchronized paths
m = 15 TC0 - Asynchronous, synchronous, and resynchronized paths
m = 16 TC1 - Asynchronous, synchronous, and resynchronized paths
m = 17 TC2 - Asynchronous, synchronous, and resynchronized paths
m = 18 TC3 - Asynchronous, synchronous, and resynchronized paths
m = 19 ADC START ADC start conversion Asynchronous, synchronous, and resynchronized paths
m = 20 ADC SYNC Flush ADC Asynchronous, synchronous, and resynchronized paths
m = 21 AC COMP0 Start comparator 0 Asynchronous, synchronous, and resynchronized paths
m = 22 AC COMP1 Start comparator 1 Asynchronous, synchronous, and resynchronized paths
m = 23 PTC STCONV PTC start conversion Asynchronous, synchronous, and resynchronized paths
m = 24 CCL LUTIN 0 CCL input Asynchronous, synchronous, and resynchronized paths
m = 25 CCL LUTIN 1 CCL input Asynchronous, synchronous, and resynchronized paths
m = 26 CCL LUTIN 2 CCL input Asynchronous, synchronous, and resynchronized paths
m = 27 CCL LUTIN 3 CCL input Asynchronous, synchronous, and resynchronized paths
m = 29 MTB START Tracing start Asynchronous, synchronous, and resynchronized paths
m = 30 MTB STOP Tracing stop Asynchronous, synchronous, and resynchronized paths