Table 3-22. Current Consumption ATmega165PA TA = -40°C to 105°C, VCC = 1.8V to 5.5V (unless otherwise noted)
Symbol Parameter Condition Min. Typ. Max. Units
ICC Power supply current(1) Active 1 MHz, VCC = 2V 0.4 0.5 mA
Active 4 MHz, VCC = 3V 2.3 2.8 mA
Active 8 MHz, VCC = 5V 9 11
Idle 1 MHz, VCC = 2V 0.1 0.2
Idle 4 MHz, VCC = 3V 0.8 0.9
Idle 8 MHz, VCC = 5V 3.1 3.3
Power-save mode(2)

32.768 kHz TOSC enabled,

VCC = 1.8V

0.6 1.8 µA

32.768 kHz TOSC enabled,

VCC = 3V

0.9 3
Power-down mode(2) WDT enabled, VCC = 3V 7 11
WDT disabled, VCC = 3V 0.2 2.5
Note:
  1. Maximum and Typical values for 25°C. Maximum values are test limits in production.

Table 3-23. Current Consumption ATmega325A TA = -40°C to 105°C, VCC = 1.8V to 5.5V (unless otherwise noted)
Symbol Parameter Condition Min. Typ. Max. Units
ICC Power supply current(1) Active 1 MHz, VCC = 2V 0.35 0.55 mA
Active 4 MHz, VCC = 3V 1.65 2.9 mA
Active 8 MHz, VCC = 5V 5.7 11
Idle 1 MHz, VCC = 2V 0.1 0.2
Idle 4 MHz, VCC = 3V 0.4 0.90
Idle 8 MHz, VCC = 5V 1.65 3.5
Power-save mode(2)

32.768 kHz TOSC enabled,

VCC = 1.8V

µA

32.768 kHz TOSC enabled,

VCC = 3V

3
Power-down mode(2) WDT enabled, VCC = 3V 12 15
WDT disabled, VCC = 3V 4.7 5
Note:
  1. All bits are set in the ‘Power Reduction Register’ on page 42.
  2. Maximum and Typical values for 25°C. Maximum values are test limits in production.

Table 3-24. Current Consumption ATmega325PA TA = -40°C to 105°C, VCC = 1.8V to 5.5V (unless otherwise noted)
Symbol Parameter Condition Min. Typ. Max. Units
ICC Power supply current(1) Active 1 MHz, VCC = 2V 0.35 0.55 mA
Active 4 MHz, VCC = 3V 1.65 2.9
Active 8 MHz, VCC = 5V 5.7 11
Idle 1 MHz, VCC = 2V 0.1 0.2
Idle 4 MHz, VCC = 3V 0.4 0.90
Idle 8 Hz, VCC = 5V 1.65 3.5
Power-save mode(2)

32.768 kHz TOSC enabled,

VCC = 1.8V

µA

32.768 kHz TOSC enabled,

VCC = 3V

3
Power-down mode(2) WDT enabled, VCC = 3V 12 15
WDT disabled, VCC = 3V 4.7 5
Note:
  1. All bits are set in the ‘Power Reduction Register’ on page 42.
  2. Maximum and Typical values for 25°C. Maximum values are test limits in production.

Table 3-25. Current Consumption ATmega3250A TA = -40°C to 105°C, VCC = 1.8V to 5.5V (unless otherwise noted)
Symbol Parameter Condition Min. Typ. Max. Units
ICC Power supply current(1) Active 1 MHz, VCC = 2V 0.35 0.55 mA
Active 4 MHz, VCC = 3V 1.65 2.9
Active 8 MHz, VCC = 5V 5.7 11
Idle 1 MHz, VCC = 2V 0.1 0.2
Idle 4 MHz, VCC = 3V 0.4 0.90
Idle 8 MHz, VCC = 5V 1.65 3.5
Power-save mode(2)

32.768 kHz TOSC enabled,

VCC = 1.8V

µA

32.768 kHz TOSC enabled,

VCC = 3V

3
Power-down mode(2) WDT enabled, VCC = 3V 12 15
WDT disabled, VCC = 3V 4.7 5
Note:
  1. All bits are set in the ‘Power Reduction Register’ on page 42.
  2. Maximum and Typical values for 25°C. Maximum values are test limits in production.

Table 3-26. Current Consumption ATmega3250PA TA = -40°C to 105°C, VCC = 1.8V to 5.5V (unless otherwise noted)
Symbol Parameter Condition Min. Typ. Max. Units
ICC Power supply current(1) Active 1 MHz, VCC = 2V 0.35 0.55 mA
Active 4 MHz, VCC = 3V 1.65 2.9
Active 8 MHz, VCC = 5V 5.7 11
Idle 1 MHz, VCC = 2V 0.1 0.2
Idle 4 MHz, VCC = 3V 0.4 0.90
Idle 8 MHz, VCC = 5V 1.65 3.5
Power-save mode(2)

32.768 kHz TOSC enabled,

VCC = 1.8V

µA

32.768 kHz TOSC enabled,

VCC = 3V

3
Power-down mode(2) WDT enabled, VCC = 3V 12 15
WDT disabled, VCC = 3V 4.7 5