7.6 Power-Up Sequence
The characteristics of power-up sequence are as follows:
- The VDD/AVDD domains must rise at the same time
- On power-up, PIC32CX-BZ2 always start up on the MLDO mode
- After power-up in MLDO, the software can initiate the switch to Buck mode