6 AC Read Characteristics

Table 6-1. AC Read Characteristics
ParameterSymbolAT28HC64B‑70AT28HC64B‑90AT28HC64B‑120AT28HC64BF‑120Units
Min.Max.Min.Max.Min.Max.Min.Max.
Address to Output DelaytACC7090120120ns
CE to Output DelaytCE(1)7090120120ns
OE to Output DelaytOE(2)035040050050ns
CE or OE to Output FloattDF(3,4)035040050050ns

Output Hold from OE, CE or Address, whichever occurred first

tOH0000ns