Setting the
CONT bit automatically
retriggers a new conversion cycle after updating the
ADACC register. That means the
GO bit remains set to
generate automatic retriggering. If
SOI =
1
, a Threshold Interrupt condition will clear the GO bit and the conversion will
stop.