34.10.1 Read Waveforms

The following figure shows the read cycle. The read cycle starts with the address setting on the memory address bus:
  • {A[25:2], A1, A0} for 8-bit devices
  • {A[25:2], A1} for 16-bit devices
  • {A[25:2] for 32-bit devices
Figure 34-8. Standard Read Cycle