4.1.3 DUT TX and RX on a Low-Impedance Network

CAUTION: For this part of the test, the user must set up the Configuration B, refer to the Figure 2-6.
Important: Modify the TestATT_[g3|prime].conf file, setting the ‘path’ as ‘tx_rx’ and ‘tester_impedance’ as ‘2’ (Vlow-Impedance mode).
Run the TestATT_[g3|prime].py script according to the customer-specific configuration depending on their possibilities:
C:\PHYperformance>python.exe TestATT_g3.py
C:\Python37\lib\site-packages\visa.py
Physical G3 DUT Testing Tool
Physical Attenuator NOT present!!!
Physical DUT Testing Tool
Set Attenuation to  0
Press Enter to continue...
Completed: 0.000000 %
ATTENUATION: 0
BPSK_ROBO , DIFFERENTIAL
FER = 0.000000 %
Completed: 8.333333 %
ATTENUATION: 0
BPSK , DIFFERENTIAL
FER = 0.000000 %
Completed: 16.666667 %
ATTENUATION: 0
BPSK_ROBO , COHERENT
FER = 0.000000 %
Completed: 25.000000 %
ATTENUATION: 0
BPSK , COHERENT
FER = 0.000000 %
Set Attenuation to  5
Press Enter to continue...
Completed: 33.333333 %
ATTENUATION: 5
BPSK_ROBO , DIFFERENTIAL
FER = 0.000000 %
Completed: 41.666667 %
ATTENUATION: 5
BPSK , DIFFERENTIAL
FER = 0.000000 %
Completed: 50.000000 %
ATTENUATION: 5
BPSK_ROBO , COHERENT
FER = 0.000000 %
Completed: 58.333333 %
ATTENUATION: 5
BPSK , COHERENT
FER = 0.000000 %
Set Attenuation to  10
Press Enter to continue...
Completed: 66.666667 %
ATTENUATION: 10
BPSK_ROBO , DIFFERENTIAL
FER = 0.000000 %
Completed: 75.000000 %
ATTENUATION: 10
BPSK , DIFFERENTIAL
FER = 0.000000 %
Completed: 83.333333 %
ATTENUATION: 10
BPSK_ROBO , COHERENT
FER = 0.000000 %
Completed: 91.666667 %
ATTENUATION: 10
BPSK , COHERENT
FER = 0.000000 %
FINISHED with completed: 100.000000 %
Test finished, Duration:0:09:33
Sending e-mail report to username@domain.com
E-mail sent.