13.11.7.2 Clock Domains
(Ask a Question)- Include inter-clock domains in calculations for timing analysis: Allows you to specify whether SmartTime must use inter-clock domains in calculations for timing analysis. By default, this option is checked.
- Enable recovery and removal checks: Allows SmartTime to check removal and recovery time on asynchronous signals. Additional sets are created in each clock domain in Analysis View to report the corresponding paths.