66.20.2 Timing Extraction

Figure 66-38. PDMIC Timing Diagram
Table 66-87. PDMIC IOSET1 Timings
SymbolPower Supply1.8V3.3VUnit
ParameterMinMaxMinMax
PDMIC0DATA setup time right3.5–3.5–ns
PDMIC1DATA hold time right3.1–3.5–ns
PDMIC2DATA setup time left3.5–3.5–ns
PDMIC3DATA hold time left3.1–3.5–ns
Table 66-88. PDMIC IOSET2 Timings
SymbolPower Supply1.8V3.3VUnit
ParameterMinMaxMinMax
PDMIC0DATA setup time right4.2–4.2–ns
PDMIC1DATA hold time right2–2–ns
PDMIC2DATA setup time left4.2–4.2–ns
PDMIC3DATA hold time left2–2–ns