1.1.4.41 DRV_METROLOGY_MEASURE_TYPE Enum

C
typedefenum {
    MEASURE_UA_RMS = 0,
    MEASURE_UB_RMS,
    MEASURE_UC_RMS,
    MEASURE_IA_RMS,
    MEASURE_IB_RMS,
    MEASURE_IC_RMS,
    MEASURE_INI_RMS,
    MEASURE_INM_RMS,
    MEASURE_INMI_RMS,
    MEASURE_PT,
    MEASURE_PA,
    MEASURE_PB,
    MEASURE_PC,
    MEASURE_QT,
    MEASURE_QA,
    MEASURE_QB,
    MEASURE_QC,
    MEASURE_ST,
    MEASURE_SA,
    MEASURE_SB,
    MEASURE_SC,
    MEASURE_UAF_RMS,
    MEASURE_UBF_RMS,
    MEASURE_UCF_RMS,
    MEASURE_IAF_RMS,
    MEASURE_IBF_RMS,
    MEASURE_ICF_RMS,
    MEASURE_IMNF_RMS,
    MEASURE_PTF,
    MEASURE_PAF,
    MEASURE_PBF,
    MEASURE_PCF,
    MEASURE_QTF,
    MEASURE_QAF,
    MEASURE_QBF,
    MEASURE_QCF,
    MEASURE_STF,
    MEASURE_SAF,
    MEASURE_SBF,
    MEASURE_SCF,
    MEASURE_FREQ,
    MEASURE_FREQA,
    MEASURE_FREQB,
    MEASURE_FREQC,
    MEASURE_ANGLEA,
    MEASURE_ANGLEB,
    MEASURE_ANGLEC,
    MEASURE_ANGLEN,
    MEASURE_TYPE_NUM
} DRV_METROLOGY_MEASURE_TYPE;
Summary

Identifies all types of measurements.

Description

Values are calculated both including all harmonics and fundamental only (F added at the end of magnitude name), where:

  • U = Voltage RMS value
  • I = Current RMS value
  • P = Active power value
  • Q = Reactive power value
  • S = Aparent power value
  • FREQ = Frequency of the line voltage fundamental harmonic component determined by the Metrology library
  • ANGLE = Angle between the voltage and current vectors