38.1 Rev. A
- Reduced ADC accuracy for
Vdd from 2.7V to 4.1V.
- Description:
-
- DNL less than -1 (missing codes) can be observed for ADC codes 256, 512 and 768.
- Increased gain error.
- Fix/Workaround:
- Use Vdd below 2.7V or above 4.1V if accurate ADC is needed.