26.8.2 Quick Start Guide for TRNG - Callback

In this use case, the True Random Number Generator (TRNG) module is configured for:
  • The TRNG peripheral will not be stopped in standby sleep mode.

This use case will read random data in interrupt mode repeatly. After reading specific size of buffer data, the board LED will be toggled.