9.2 Recommended Operating Conditions

The following table provides the recommended operating conditions for the ATSAMR30M18A module.

Table 9-2. Recommended Operating Conditions
SymbolParameterMin.Typ.Max.Unit
TOPOperating temperature range-402585°C
VDDSupply voltage1.83.33.63V