7.3.2.1 Skew Matching Constraints
(Ask a Question)- The address and command groups must be skew matched with respect to CK signals within ±100 ps.
- The DQ, DM signals must be skew matched with respect to DQS within ±25 ps.
The read DQ/DQS training will adjust DQS signal to optimal sampling point based on the board skew between DQ and DQS.