1.3.11.1 Conversion Time Calculation

The conversion time is a sum of:

Tconv = Tsync_read + tsample + -tdistrib +tcal +tsync_write
Tsync_read = Tsync_write = synchronization time = sys_clk

Tacquisition_hold = Tsample + (Tprescaler_settling or Tstrobe) = ( 2 + stc ) * adc_clk

The stc is a factor of the user’s acquisition and hold time.

Tdistrib = charge distribution time = adc_resolution * adc_clock

Tcal = calibration time = 2 * adc_clk