1 AC

CTRLA.SWRST

Registers that are not reset by SWRST can be written before SYNCBUSY.SWRST is cleared.

Workaround

Monitor SYNCBUSY.SWRST after setting CTRLA.SWRST to verify it has cleared before writing to any other registers in the AC module.

Affected Silicon Revisions

A1A2
XX